Model |
SUN-10K-SG01 HP3-AU-AM2 |
SUN-12K-SG01 HP3-AU-AM2 |
SUN-15K-SG01 HP3-AU-AM2 |
SUN-20K-SG01 HP3-AU-AM2 |
SUN-25K-SG01 HP3-AU-AM2 |
Battery Input Data |
Battery Type |
Lithium-ion |
Battery Voltage Range (V) |
160-700 |
Max. Charging Current (A) |
37 |
50 |
Max. Discharging Current (A) |
37 |
50 |
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS
|
Number of Battery Input |
1
|
PV String Input Data |
Max. PV Access Power (W)
|
20000 |
24000 |
30000 |
40000 |
50000 |
Max. PV Input Power (W) |
16000 |
19200 |
24000 |
32000 |
40000 |
Rated PV Input Voltage (V) |
1000 |
Start-up Voltage(V) |
180 |
MPPT Voltage Range (V) |
150-850 |
Rated PV Input Voltage (V) |
600 |
700 |
Max. Operating PV Input Current (A) |
20+20 |
26+20 |
26+26 |
Max. Input Short-Circuit Current (A) |
30+30 |
39+30 |
39+39 |
No. of MPP Trackers/ No. of Strings MPP Tracker |
2/1+1 |
2/2+1 |
2/2+2 |
AC Output Data |
Rated AC Input/Output Active Power (W) |
10000 |
12000 |
15000 |
20000 |
25000 |
Max. AC Input/Output Apparent Power (VA) |
11000 |
13200 |
16500 |
22000 |
27500 |
Rated AC Input/Output Current (A) |
15.2/14.5 |
18.2/17.4 |
22.8/21.8 |
30.4/29 |
37.9/36.3 |
Max. AC Input/Output Current (A) |
16.7/16 |
20/19.2 |
25/24 |
33.4/31.9 |
41.7/39.9 |
Max. Continuous AC Passthrough (grid to load) (A) |
40 |
80 |
Peak Power (off-grid) (W) |
1.5 times of rated power, 10s |
Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
Rated Input/Output Voltage/Range (V) |
230/400V 240/415V 0.85Un-1.1Un |
Rated Input/Output Grid Frequency/Range(Hz) |
50Hz/45Hz-55Hz |
Grid Connection Form |
3L+N+PE |
Total Current Harmonic Distortion THDi |
<3% (of nominal power) |
DC Injection Current |
<0.5%ln |
Efficiency |
Max Efficiency |
97.60% |
Euro Efficiency |
97.00% |
MPPT Efficiency |
>99% |
Equipment Protection |
Integrated |
DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection,AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,Arc Fault Circuit Interrupter (optional), Anti-islanding Protection(Active Frequency shift), DC Switch,Insulation Impedance Detection, Residual Current Detection |
Surge Protection Level |
TYPE II(DC), TYPE II(AC) |
Interface |
Communication Interface |
WIFI,RS485/CAN |
LCD/LED Display |
LCD |
General Data |
Operating Temperature Range (℃) |
-40 to +60℃, >45℃ derating |
Permissible Ambient Humidity |
0-100% |
Permissible Altitude |
2000m |
Noise (dB) |
≤55 |
Ingress Protection(IP) Rating |
IP 65 |
Inverter Topology |
Non-Isolated |
Over Voltage Category |
OVC II(DC), OVC III(AC) |
Cabinet Size (WxHxD mm) |
408×638×237 (Excluding Connectors and Brackets) |
Weight (kg) |
30.5 |
Type of Cooling |
Intelligent Air Cooling |
Warranty |
10 Years |
Grid Regulation |
AS/NZS 4777.2 |
Safety EMC / Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |