Model |
SUN-29.9K-SG01HP3-AU-BM3 |
SUN-35K-SG01HP3 -AU-BM3 |
SUN-40K-SG01HP3 -AU-BM4 |
SUN-50K-SG01HP3 -AU-BM4 |
Battery Input Data |
|
Battery Type |
Lithium-ion |
Battery Voltage Range(V) |
160-800 |
Max.Charging Current(A) |
50+50 |
Max.Discharging Current(A) |
50+50 |
Charging Strategy for Li-ion Battery |
Self-adaption to BMS |
Number of Battery Input |
2 |
PV String Input Data |
|
|
|
Max PV Input Power(W) |
38870
|
39000
|
|
65000
|
Max. PV Input Voltage (V) |
1000 |
Start-up Voltage(V) |
180 |
Min Input PV Operating Voltage Range (V) |
180-1000 |
MPPT Range (V) |
150-850 |
Full Load PV Voltage Range (V) |
360-850 |
420-850 |
360-850 |
450-850 |
Rated PV Input Voltage (V) |
600 |
Max. PV ISC(A) |
55+55+55 |
55+55+55+55 |
PV Input Current (A) |
36+36+36 |
36+36+36+36 |
No.of MPP Trackers |
3 |
4 |
No.of Strings per MPP Tracker |
2+2+2 |
2+2+2+2 |
AC Output Data |
|
|
|
Rated AC Output Active Power(W) |
29900 |
35000 |
40000 |
50000 |
Rated Apparent Output Power (VA) |
29900 |
35000 |
40000 |
50000 |
Max. AC Output Power (W) |
29900 |
35000 |
40000 |
50000 |
AC Output Rated Current (A) |
43.4 |
50.8 |
58 |
72.5 |
Max AC Output Current(A) |
43.4 |
50.8 |
58 |
72.5 |
Max. Three-phase Unbalanced Output Current (A) |
60 |
60 |
70 |
83.3 |
Max Continuous AC Passthrough (A) |
200 |
Peak Power (off grid) |
1.5 times of rated power, 10s |
Generator Input/Smart Load /AC Couple Current (A) |
43.4 / 200 / 43.4 |
50.8 / 200 / 50.8 |
58 / 200 / 58 |
72.5 / 200 / 72.5 |
Power Factor Adjustment Range |
0.8 leading-0.8lagging |
Output Frequency and Voltage |
50/60Hz; 3L/N/PE 220/380, 230/400Vac |
Grid Type
|
Three Phase
|
Total Harmonics Current Distortion (THDi) |
<3% (of nominal power) |
DC current injection |
<0.5%ln |
Efficiency |
|
Max Efficiency |
97.60% |
Euro Efficiency |
97.00% |
MPPT Efficiency |
>99.9% |
Equipment Protection |
|
Integrated |
Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge Protection, Arc Fault Circuit Interruption (AFCI optional) |
Protection Level |
Class I |
Over Voltage Category |
DC Type II/AC Type III |
Certifications and Standards |
|
Grid Regulation |
AS/NZS 4777.2 |
Safety EMC / Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
General Data |
|
Operating Temperature Range (℃) |
-40 to +60℃, >45℃ Derating |
Cooling |
Smart cooling |
Noise (dB) |
≤65 dB |
Communication with BMS |
CAN |
Weight (kg) |
80 |
Size (mm) |
527W×894H×294D(Excluding connectors and brackets) |
Protection Degree |
IP65 |
Installation Style |
Wall-mounted |
Inverter topology |
Non-isolated |
Warranty |
5 Years (10 Years Optional)
|