| Model | SUN-29.9K-SG01HP3-AU-BM3 | SUN-30K-SG01HP3-AU-BM3 | SUN-35K-SG01HP3-AU-BM3 | SUN-40K-SG01HP3-AU-BM4 | SUN-50K-SG01HP3-AU-BM4 |
| Battery Input Data | |||||
| Battery Type | Lithium-ion | ||||
| Battery Voltage Range(V) | 160-800 | ||||
| Max.Charging/Discharging Current(A) | 50+50 | ||||
| Charging Strategy for Li-ion Battery | Self-adaption to BMS | ||||
| Number of Battery Input | 2 | ||||
| PV String Input Data | |||||
|
Max. PV access power(W)
|
50000 | 60000 | 70000 | 80000 | 100000 |
| Max. PV Input Power(W) | 44850 | 45000 | 52500 | 60000 | 75000 |
| Max. PV Input Voltage (V) | 1000 | ||||
| Start-up Voltage(V) | 180 | ||||
| MPPT Voltage Range (V) | 150-850 | ||||
| Rated PV Input Voltage (V) | 600 | ||||
| Max. Operating PV Input Current (A) | 36+36+36 |
36+36+36+36 | |||
| Max. Input Short-Circuit Current (A) | 55+55+55 |
55+55+55+55 | |||
| No. of MPP Trackers/ No. of Strings MPP Tracker |
3/2+2+2 |
4/2+2+2+2 | |||
| AC Input/Output Data | |||||
| Rated AC Input/Output Active Power(W) | 29900 | 30000 | 35000 | 40000 | 50000 |
| Rated/Max. AC Input/Output Apparent Power(VA) | 29900 | 30000 | 35000 | 40000 | 50000 |
| Rated AC Input/Output Current(A) | 43.4 | 43.5 | 50.8 | 58 | 72.5 |
| Max. AC Input/Output Current(A) | 43.4 | 43.5 | 50.8 | 58 | 72.5 |
| Max. Continuous AC Passthrough(grid to load)(A) | 200 | ||||
| Peak Power(off grid)(W) | 1.5 times of rated power, 10s | ||||
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
| Rated Input/Output Voltage | 230/400V 240/415V 0.85Un-1.1Un 3L+N+PE | ||||
| Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55 | ||||
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||||
| DC Injection Current | <0.5%ln | ||||
| Generator Data | |||||
| Nominal Input Voltage (V) | 230/400V, 240/415V | ||||
| Rated Input Current (A) | 200 | ||||
| Power Factor | 0.8 leading-0.8 lagging | ||||
| Frequency | 50Hz | ||||
| Backup Data | |||||
| Nominal Output Voltage (V) | 230/400V,240/415V | ||||
| Rated Output Current (A) | 43.4 | 43.5 | 50.8 | 58 | 72.5 |
| Rated Apparent Power (VA) | 29900 | 30000 | 35000 | 40000 | 50000 |
| Power Factor | 0.8 leading-0.8 lagging | ||||
| Frequency | 50Hz | ||||
| Efficiency | |||||
| Max. Efficiency | 97.6% | ||||
| Euro Efficiency | 97.0% | ||||
| MPPT Efficiency | >99% | ||||
| Equipment Protection | |||||
| Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection,AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter(AFCI)(optional),Anti-islanding Protection(Active Frequency shift) ,DC Switch,Insulation Impedance Detection,Residual Current Detection | ||||
| Surge Protection Level | TYPE II(DC), TYPE II(AC) | ||||
| Interface | |||||
| LCD/LED Display |
LCD
|
||||
| Communication Interface | WIFI,RS485/CAN | ||||
| General Data | |||||
| Operating Temperature Range (℃) | -40 to +60℃, >45℃ Derating | ||||
| Permissible Ambient Humidity | 0-100% | ||||
| Permissible Altitude | 2000m | ||||
| Noise (dB) | ≤65 | ||||
| Ingress Protection(IP) Rating | IP 65 | ||||
|
Protection Level |
Class I |
||||
| Inverter Topology | Non-Isolated | ||||
| Over Voltage Category | OVC II(DC), OVC III(AC) | ||||
| Cabinet Size (WxHxD mm) | 527×894×294 (Excluding Connectors and Brackets) | ||||
| Weight (kg) | 80 | ||||
| Type of Cooling | Intelligent Air Cooling | ||||
| Warranty | 10 Years | ||||
| Grid Regulation | AS/NZS 4777.2 | ||||
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||||