| Model |
SUN-3K-SG04LP1-24-AU |
SUN-3K-SG04LP1-AU |
SUN-3.6K-SG04LP1-AU |
SUN-5K-SG04LP1-AU |
SUN-6K-SG04LP1-AU |
| Battery Input Data |
| Battery Type |
Lead-acid or Lithium-ion |
| Battery Voltage Range (V) |
20-30 |
40-60 |
| Max. Charging Current (A) |
140 |
70 |
90 |
120 |
135 |
| Max. Discharging Current (A) |
140 |
70 |
90 |
120 |
135 |
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS
|
| Number of Battery Input |
1
|
| PV String Input Data |
|
Max. PV Access Power (W)
|
6000 |
6000 |
7200 |
10000 |
12000 |
| Max. PV Input Power (W) |
4500 |
4500 |
5400 |
7500 |
9000 |
| Rated PV Input Voltage (V) |
500 |
| Start-up Voltage(V) |
125 |
| MPPT Voltage Range (V) |
150-425 |
| Rated PV Input Voltage (V) |
370 |
| Max. Operating PV Input Current (A) |
18 |
18+18 |
| Max. Input Short-Circuit Current (A) |
27 |
27+27 |
No. of MPP Trackers/ No. of Strings MPP Tracker |
1/1 |
2/1+1 |
| AC Output Data |
| Rated AC Input/Output Active Power (W) |
3000 |
3600 |
5000 |
6000 |
| Max. AC Input/Output Apparent Power (VA) |
3000 |
3600 |
5000 |
6000 |
| Rated AC Input/Output Current (A) |
13 |
15.7 |
21.7 |
26.1 |
| Max. AC Input/Output Current (A) |
13 |
15.7 |
21.7 |
26.1 |
| Max. Continuous AC Passthrough (grid to load) (A) |
35 |
40 |
| Peak Power (off-grid) (W) |
2 time of rated power, 10 S |
| Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
| Rated Input/Output Voltage/Range (V) |
230 /240 0.85Un-1.1Un |
| Rated Input/Output Grid Frequency/Range(Hz) |
50Hz/45Hz-55Hz |
| Grid Connection Form |
L+N+PE |
| Total Current Harmonic Distortion THDi |
<3% (of nominal power) |
| DC Injection Current |
<0.5%ln |
| Efficiency |
|
| Max Efficiency |
97.60% |
| Euro Efficiency |
96.50% |
| MPPT Efficiency |
99.90% |
| Protectton |
|
| Integrated |
DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection,AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,Insulation Impedance Detection, Arc Fault Circuit Interrupter (optional),DC Switch,Anti-islanding Protection(Active Frequency shift) , Residual Current Detection |
|
Surge Protection Level
|
TYPE II(DC), TYPE II(AC) |
| Interface |
|
| Communication Interface |
WIFI,RS485/CAN |
| LCD/LED Display |
LCD |
| General Data |
|
| Operating Temperature Range (℃) |
-40 to +60℃, >45℃ derating |
| Permissible Ambient Humidity |
0-100% |
| Permissible Altitude |
2000m |
| Noise (dB) |
<30 dB |
| Inverter Topology |
Non-Isolated |
| Over Voltage Category |
OVC II(DC), OVC III(AC) |
| Weight (kg) |
17 |
| Cabinet size (mm) |
330W x 433H x229D(Excluding connectors and brackets) |
| Protection Degree |
IP65 |
|
Protection Level
|
Class I
|
| Type of Cooling |
Intelligent Air Cooling |
| Warranty |
10 Years |
| Grid Regulation |
AS/NZS 4777.2 |
| Safety EMC / Standard |