Model |
SUN-3K-G04-AU |
PV String Input Date |
|
Max. PV Input Power(kW) |
4.5 |
Max. PV Input Voltage(V) |
550 |
Start-up PV Input Voltage (V) |
80 |
MPPT Operating Range (V) |
70-500 |
Rated PV Input Voltage (V)
|
360 |
Max. Operating PV Input Current (A)
|
13 |
Max. Input Short Circuit Current (A)
|
19.5 |
No. of MPP Trackers/
No. of Strings MPP Tracker
|
1/1 |
AC Output Data
|
|
Rated AC Output Active Power(kW) |
3 |
Max. AC Output Apparent Power(kVA) |
3 |
Rated AC Output current (A)
|
13 |
Max. AC Output Current(A)
|
13 |
Rated Output voltage/range (V) |
230 0.85Un-1.1Un |
|
L/N/PE
|
Rated Output Grid Frequency/range(Hz) |
50Hz/45Hz-55Hz |
Power Factor Adjustment Range |
0.8 leading to 0.8lagging |
Total Current Harmonic Distortion THDi
|
<3% |
DC Injection Current(mA) |
<0.5%ln
|
Efficiency |
|
Max. Efficiency |
97.50% |
Euro Efficiency |
97% |
MPPT Efficiency |
>99% |
Equipment Protection |
|
DC Polarity Reverse Connection
Protection
|
yes |
AC Output Overcurrent Protection
|
yes |
AC Output Overvoltage Protection
|
yes |
AC Output Short Circuit Protection
|
yes |
Thermal Protection
|
yes |
DC Terminal Insulation Impedance
Monitoring
|
yes |
DC Component Monitoring
|
yes |
Ground Fault Current Monitoring
|
yes |
Arc Fault Circuit Interrupter (AFCI)
|
Optional
|
Power Network Monitoring
|
yes |
Island Protection Monitoring
|
yes
|
Earth Fault Detection
|
yes |
Overvoltage Load Drop Protection
|
yes |
Residual Current (RCD) Detection
|
yes |
Surge Protection Level |
TYPE II(DC), TYPE II(AC) |
Interface
|
|
Communication Interface |
RS485/RS232/CAN |
Monitor Mode
|
GPRS/WIFI/Bluetooth/4G/LAN(optional) |
General Data |
|
Operating Temperature Range (°C) |
-25 to +65℃, >45℃ derating |
Permissible Ambient Humidity |
0~100% |
Permissible Altitude (m) |
2000m |
Noise (dB) |
≤ 35dB |
Ingress Protection(IP) Rating |
IP 65 |
Over Voltage Category |
OVC II(DC), OVC III(AC) |
Size (mm) |
280W×310H×184 D (Excluding Connectors and Brackets)
|
Weight [kg] |
4.8 |
Warranty |
10 years |
Type of Cooling |
Natural Cooling |
Grid Connection Standard |
AS/NZS 4777.2 |
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |