Model |
SUN-9K-G02P1-AU-AM2 |
SUN-10K-G02P1-AU-AM2 |
SUN-10.5K-G02P1-AU-AM2 |
PV String Input Date |
|
Max. PV Input Power(kW) |
13.5 |
15 |
15.8 |
Max. PV Input Voltage(V) |
550 |
Start-up Voltage(V) |
80 |
MPPT voltage range(V) |
70-500 |
Rated PV Input voltage(V) |
360 |
Max. Input Short Circuit Current (A) |
39+39 |
Max. Operating PV Input Current(A) |
26+26 |
No. of MPP Trackers/No. of Strings per MPP Tracker |
2/2+2 |
AC Output Side
|
|
Rated AC Output Active Power(kW) |
9 |
9.99 |
10.5 |
Max. AC Output Apparent Power(kVA) |
9 |
9.99 |
10.5 |
Rated AC output current (A) |
39.2
|
43.5 |
45.7 |
Max. AC Output Current(A) |
39.2 |
43.5 |
45.7 |
Rated output voltage/range (V) |
220/230 0.85Un-1.1Un |
Grid Connection Form |
L/N/PE |
Rated Output Grid Frequency/range(Hz) |
50/45-55 |
Power Factor Adjustment Range |
0.8 leading to 0.8lagging |
Total Current Harmonic Distortion THDi |
<3% |
DC Injection Current |
<0.5%ln |
Efficiency |
|
Max. Efficiency |
97.7% |
Euro Efficiency |
97.2% |
MPPT Efficiency |
>99% |
Equipment Protection |
|
DC Polarity Reverse Connection Protection |
yes |
AC Output Overcurrent Protection |
yes |
AC Output Overvoltage Protection |
yes |
AC Output Short Circuit Protection |
yes |
Thermal Protection |
yes |
DC Terminal Insulation Impedance Monitoring |
yes |
DC Component Monitoring |
yes |
Ground Fault Current Monitoring |
yes |
Arc Fault Circuit Interrupter (AFCI)
|
Optional
|
Power Network Monitoring |
yes |
Island Protection Monitoring |
yes |
Earth Fault Detection |
yes |
Overvoltage Load Drop Protection |
yes |
Residual Current (RCD) Detection |
yes |
Surge Protection Level |
TYPE II(DC),TYPE II(AC) |
Interface |
|
Communication Interface |
RS485
|
Monitor Mode
|
GPRS/WIFI/Bluetooth/4G/LAN(optional) |
General Data |
|
Operating Temperature Range (°C) |
-25 to +60℃, >45℃ Derating |
Permissible Ambient Humidity |
0~100% |
Permissible Altitude (m) |
3000m |
Noise (dB) |
≤ 35 |
Ingress Protection(IP) Rating |
IP 65 |
Inverter Topology |
Transformerless |
Over Voltage Category |
OVC II(DC),OVC III(AC) |
Cabinet Size (WxHxD mm) |
330*410*213.5(Excluding connectors and brackets) |
Weight [kg] |
14.8 |
Warranty |
5 years |
Type Of Cooling |
natural cooling |
Grid Regulation |
AS/NZS 4777.2 |
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |